This diagram is from the service manual of a combi boiler. It’s a flow sensor which detects whether hot water is running, which is then used to trigger on-demand heat and switch a diverter to take radiators out of the loop.

In English, the diagram shows:

  • X ⅔ red wire (+5V)
  • X 2/2 black wire (ground)
  • X 2/6 green wire (signal)

I need to know what those fractions mean. I took the voltage measurements in this video:

I cannot necessarily trust the model in that video to have the same specs as mine. My voltmeter detected 4.68 V on the red input wire showing that the sensor is well fed. The green “signal” wire is supposed to be 0 V at rest and 2 V with water running (or I think the reverse of that is used in some models). In my case the green wire is ~1.33 V at rest and ~0.66 V when water is running. I need to know if these readings are normal as I troubleshoot this problem.

  • crimsonpoodle
    link
    fedilink
    arrow-up
    1
    ·
    3 months ago

    No idea on the fractions however what does the sensor wire connect to? If you know the specifications of the next component you could maybe tell if the 1.33v or 0.66 is enough to trigger it. But I would guess it’s functioning probably given that it changes so dramatically, although I wonder why it’s not getting the full 5v?