Gas stoves fill the air in your home with particulate matter (pm), which has been found to increase cancer risk in the long term.

So next time you buy a stove, consider choosing an induction stove.

Btw, gas stoves being better or faster than induction is a myth. They have certain specific advantages, but they are actually slower.

Obligatory Technology Connections video:
https://www.youtube.com/watch?v=eUywI8YGy0Y

  • hinterlufer@lemmy.world
    link
    fedilink
    arrow-up
    20
    arrow-down
    2
    ·
    9 hours ago

    1 kW is 3412 BTU/h (=BTUs)

    Most induction stovetops have a boost function with around 3-4 kW (that’s about 13000 BTUs).

    BUT contrary to a gas stove top, almost all of the energy is actually put into the pot instead of the surroundings (only 30-40% of the energy from a gas stove is used to heat the pot). Meaning that a 4 kW induction cooktop should be comparable to a 40’000 BTUs gas stove (single burner).

    • HelixDab2@lemm.ee
      link
      fedilink
      arrow-up
      3
      ·
      6 hours ago

      Okay, good deal. So, in theory, an induction stove that’s 3500W should be approaching the heating ability of a typical commercial range.

      • RvTV95XBeo@sh.itjust.works
        link
        fedilink
        arrow-up
        3
        ·
        4 hours ago

        Yes, and you can test it pretty easily by just seeing how much faster a pot of water boils on induction, on-par with the boiling times of commercial burners.

        Also, in a commercial setting, induction stoves cook just as effectively with less energy which means they don’t put out nearly as much heat to the environment. For a chef, its the difference between working all day in 90-degree spaces to 70-degree AC. I’m an engineer who works on a lot of commercial kitchens (among other things), and our chefs love the electric kitchens we’ve delivered.

        When you’re cooking for work, 8+ hours a day, being comfortable while you do it is a major game changer.

        The other thing they enjoy is the level of control and consistency - many professional induction ranges will let you control on temperature, which means you can quickly adjust to specific values in order to, say, sear a steak at 500, then finish it at 300 until it hits the desired internal temperature.

    • Kbobabob@lemmy.world
      link
      fedilink
      arrow-up
      4
      arrow-down
      2
      ·
      8 hours ago

      4 kW induction cooktop should be comparable to a 40’000 BTUs gas stove (single burner).

      So this is 4000 watts? What household circuit can support that?

      • JustEnoughDucks@feddit.nl
        link
        fedilink
        arrow-up
        1
        ·
        4 hours ago

        Uhhh, tons of people in Europe are on 240V 3 phase power.

        My oven is 3100W and that is just fine. 3 phase consumer induction cooktops can easily go that high or higher.

        Once my 3 phase charging pole is put in, my car will charge at >10000W on a household circuit.

      • warbond@lemmy.world
        link
        fedilink
        arrow-up
        7
        ·
        8 hours ago

        A random Better Homes and Gardens article clocks a 2000 square ft (185 square meters) home with central air conditioning at nearly 19,000 watts.

        https://www.bhg.com/home-improvement/electrical/how-to-check-your-homes-electrical-capacity/

        So I think most homes could handle that in general, but I don’t know about specific wiring requirements to handle that kind of power draw from just the kitchen. So do these things require that level of retrofit?

          • gonzo-rand19@moist.catsweat.com
            link
            fedilink
            arrow-up
            4
            ·
            6 hours ago

            I’m confused as to why you’re so confident. The US has 3-phase power and homes get 120V from line 1 to the neutral (split-phase). If you use line 1 and 2, you get 240V. More than enough to power an oven. This is the case in every modern residential home in the US because they have a national building code.

            • Kbobabob@lemmy.world
              link
              fedilink
              arrow-up
              1
              arrow-down
              3
              ·
              5 hours ago

              Yes, I’m aware that you can do this but there are not readily available outlets throughout a home for this, lol. Yes, let me move my stove or dryer so I can plug my wok induction stove in.

              • gonzo-rand19@moist.catsweat.com
                link
                fedilink
                arrow-up
                5
                ·
                5 hours ago

                …You do know that an oven needs a dedicated outlet, yes? As in, if you don’t have a 30-50A receptacle in your home, one must be installed in order for you to have an oven. All new builds and most existing buildings have this dedicated outlet.

                Edit: I see that you’re using stove and oven separately. I am talking about a range (oven and stovetop combined), since where I live these are most common and “oven” and “stovetop” are roughly interchangeable. Apologies for any confusion.

          • Zeoic@lemmy.world
            link
            fedilink
            English
            arrow-up
            8
            ·
            edit-2
            7 hours ago

            Yes it is? The US very much has 220v for power hungry stuff. Things like ev chargers, central ac units, water heaters, electric clothes dryers, etc. It uses quite the variety of different plugs for the various amperages

            Edit: technically its 220v*

      • Aedis@lemmy.world
        link
        fedilink
        arrow-up
        4
        ·
        8 hours ago

        Idk about my math but most American household circuits require stoves to be on a (220V) dual phase 18 amp circuit. Which should output around 8kW (18A * 220V)

        • gonzo-rand19@moist.catsweat.com
          link
          fedilink
          arrow-up
          6
          ·
          6 hours ago

          Should be a lot more than 18A. Should be closer to 30A-50A to account for usage. 18A is what a kitchen receptacle would require and is so low that an oven on a 18A breaker would trip constantly. I’m Canadian so I mostly know the CEC but the NEC requirements in the USA are very similar.

          More info if you’re interested.

      • Damage@feddit.it
        link
        fedilink
        arrow-up
        1
        ·
        6 hours ago

        Here in Italy most houses used to have contacts allowing max 3kW, but nowadays it’s more common to have 4.5kW (with smart utility meters which allow 30% over current for 3 hours).
        Still have to be careful if you’re running a washing machine or something like that, but it’s doable.

        Of course old houses may have insufficiently-sized wires, and that’s another can of worms.